rem WIX Installer files (.msi) destination folder - set for local environment.\r
set IDIR=%SystemRoot%\temp\r
\r
-\r
if "%1" == "msi-label" (\r
pushd %IDIR%\r
if exist WOF_wxp_x86.msi (\r
)\r
\r
echo %0 - Building with WDK @ %_DDK%\r
-echo Building for OPENIB_REV %SVN%, installer files @ %IDIR%\r
+echo Building for OPENIB_REV %SVN%, installer files (.msi) @ %IDIR%\r
echo Drivers signed using Certificate '%CERTFILE%'\r
\r
rem pause thoughtfully.\r
call %CD%\etc\clean-build.bat\r
)\r
\r
-rem ********* Compile for WLH - Windows Server 2008 & Vista\r
+rem ************ Setup Env for Building \r
\r
+set WDK_PATH=%_DDK%\r
+set WINOF_PATH=%CD%\r
+set OPENIB_REV=%SVN%\r
+set PLATFORM_SDK_PATH=%_PSDK%\r
+\r
+rem ********* Compile for WLH - Windows Server 2008 & Vista\r
rem WLH x64\r
echo %0 - Build WLH x64 Checked\r
-%COMSPEC% /C "call %BSE%\etc\IB_CHK_BLD_x64.bat %SVN% %CD% %_DDK% %_PSDK% WLH & build %OPS%"\r
+%COMSPEC% /C "call %BSE%\etc\bldwo.bat chk x64 2008 %OPS%"\r
if ERRORLEVEL 1 exit /B 1\r
echo %0 - Build WLH x64 Free\r
-%COMSPEC% /C "call %BSE%\etc\IB_FRE_BLD_x64.bat %SVN% %CD% %_DDK% %_PSDK% WLH & build %OPS%"\r
+%COMSPEC% /C "call %BSE%\etc\bldwo.bat fre x64 2008 %OPS%"\r
if ERRORLEVEL 1 exit /B 1\r
\r
rem WLH x86\r
\r
echo %0 - Build WLH x86 Checked\r
-%COMSPEC% /C "call %BSE%\etc\IB_CHK_BLD_x86.bat %SVN% %CD% %_DDK% %_PSDK% WLH & build %OPS%"\r
+%COMSPEC% /C "call %BSE%\etc\bldwo.bat chk x86 2008 %OPS%"\r
if ERRORLEVEL 1 exit /B 1\r
echo %0 - Build WLH x86 Free\r
-%COMSPEC% /C "call %BSE%\etc\IB_FRE_BLD_x86.bat %SVN% %CD% %_DDK% %_PSDK% WLH & build %OPS%"\r
+%COMSPEC% /C "call %BSE%\etc\bldwo.bat fre x86 2008 %OPS%"\r
if ERRORLEVEL 1 exit /B 1\r
\r
rem WLH ia64\r
echo %0 - Build WLH ia64 Checked\r
-%COMSPEC% /C "call %BSE%\etc\IB_CHK_BLD_IA64.bat %SVN% %CD% %_DDK% %_PSDK% WLH & build %OPS%"\r
+%COMSPEC% /C "call %BSE%\etc\bldwo.bat chk ia64 2008 %OPS%"\r
if ERRORLEVEL 1 exit /B 1\r
echo %0 - Build WLH ia64 Free\r
-%COMSPEC% /C "call %BSE%\etc\IB_FRE_BLD_IA64.bat %SVN% %CD% %_DDK% %_PSDK% WLH & build %OPS%"\r
+%COMSPEC% /C "call %BSE%\etc\bldwo.bat fre ia64 2008 %OPS%"\r
if ERRORLEVEL 1 exit /B 1\r
\r
\r
rem ********* WXP - Windows XP - x86 only\r
\r
echo %0 - Build XP x86 Checked\r
-%COMSPEC% /C "call %BSE%\etc\IB_CHK_BLD_x86.bat %SVN% %CD% %_DDK% %_PSDK% WXP & build %OPS%"\r
+%COMSPEC% /C "call %BSE%\etc\bldwo.bat chk x86 xp %OPS%"\r
if ERRORLEVEL 1 exit /B 1\r
\r
echo %0 - Build XP x86 Free\r
-%COMSPEC% /C "call %BSE%\etc\IB_FRE_BLD_x86.bat %SVN% %CD% %_DDK% %_PSDK% WXP & build %OPS%"\r
+%COMSPEC% /C "call %BSE%\etc\bldwo.bat fre x86 xp %OPS%"\r
if ERRORLEVEL 1 exit /B 1\r
\r
\r
rem ********* WNET - Windows Server 2003\r
echo %0 - Build WNET x64 Checked\r
-%COMSPEC% /C "call %BSE%\etc\IB_CHK_BLD_x64.bat %SVN% %CD% %_DDK% %_PSDK% WNET & build %OPS%"\r
+%COMSPEC% /C "call %BSE%\etc\bldwo.bat chk x64 2003 %OPS%"\r
if ERRORLEVEL 1 exit /B 1\r
echo %0 - Build WNET x64 Free\r
-%COMSPEC% /C "call %BSE%\etc\IB_FRE_BLD_x64.bat %SVN% %CD% %_DDK% %_PSDK% WNET & build %OPS%"\r
+%COMSPEC% /C "call %BSE%\etc\bldwo.bat fre x64 2003 %OPS%"\r
if ERRORLEVEL 1 exit /B 1\r
\r
echo %0 - Build WNET x86 Checked\r
-%COMSPEC% /C "call %BSE%\etc\IB_CHK_BLD_x86.bat %SVN% %CD% %_DDK% %_PSDK% WNET & build %OPS%"\r
+%COMSPEC% /C "call %BSE%\etc\bldwo.bat chk x86 2003 %OPS%"\r
if ERRORLEVEL 1 exit /B 1\r
echo %0 - Build WNET x86 Free\r
-%COMSPEC% /C "call %BSE%\etc\IB_FRE_BLD_x86.bat %SVN% %CD% %_DDK% %_PSDK% WNET & build %OPS%"\r
+%COMSPEC% /C "call %BSE%\etc\bldwo.bat fre x86 2003 %OPS%"\r
if ERRORLEVEL 1 exit /B 1\r
\r
echo %0 - Build WNET ia64 Checked\r
-%COMSPEC% /C "call %BSE%\etc\IB_CHK_BLD_IA64.bat %SVN% %CD% %_DDK% %_PSDK% WNET & build %OPS%"\r
+%COMSPEC% /C "call %BSE%\etc\bldwo.bat chk ia64 2003 %OPS%"\r
if ERRORLEVEL 1 exit /B 1\r
echo %0 - Build WNET ia64 Free\r
-%COMSPEC% /C "call %BSE%\etc\IB_FRE_BLD_IA64.bat %SVN% %CD% %_DDK% %_PSDK% WNET & build %OPS%"\r
+%COMSPEC% /C "call %BSE%\etc\bldwo.bat fre ia64 2003 %OPS%"\r
if ERRORLEVEL 1 exit /B 1\r
\r
if "%1" == "compile" goto finito\r